Ford Mustang (1999-2004) Service Manual: Air Cleaner Outlet Pipe - 4.6L (4V)

Removal and Installation

Cobra

1. Disconnect the intake air temperature (IAT) sensor.

Cobra

All vehicles

2. Disconnect the vacuum hose.

All vehicles

3. Disconnect the breather hose.

All vehicles

NOTE: Cobra shown, Mach I similar.

4. Loosen the clamps and remove the air cleaner outlet pipe.

All vehicles

5. To install, reverse the removal procedure.

    Air Cleaner Outlet Pipe - 3.8L
    Removal and Installation 1. Remove the air cleaner outlet tube. 1. Loosen the clamps. 2. Disconnect the hose. 3. Remove the tube. 2. To install, reverse the removal procedure. Air Clea ...

    Air Cleaner - 3.8L
    Removal and Installation 1. Remove the air cleaner outlet tube from the throttle body. For additional information, refer to Air Cleaner Outlet Pipe-3.8L in this section. 2. Disconnect the connec ...

    Other materials:

    Electronic Vibration Analyzer (EVA)
    The EVA is a hand-held electronic diagnostic tool which will assist in locating the source of unacceptable vibrations. The vibration sensor can be remotely mounted anywhere in the vehicle for testing purposes. The unit displays the three most common vibratio ...

    Degas Bottle
    Removal and Installation 1. Drain the coolant. For additional information, refer to Supercharger Cooling System Draining, Filling and Bleeding in this section. 2. Disconnect the coolant hoses. 3. Remove the bolts and the degas bottle. 4. To install ...

    Disc Check
    Special Tool(s) Brake/Automobile Brake Drum System with Vacuum 164-R3622 or equivalent Dial Indicator/Magnetic Base 100-D002 (D78P-4201-B) or equivalent WARNING: Dust and dirt present on wheel brake and clutch assemblies may ...