Ford Mustang (1999-2004) Service Manual: Blower Motor

Removal

1. Disconnect the jumper wire.

Blower Motor

2. Disconnect the main harness.

Blower Motor

3. Remove the screws.

Blower Motor

4. Separate the cover from the motor.

Blower Motor

5. Separate the motor from the housing.

Blower Motor

6. Disconnect the jumper from the motor.

  • Remove the blower motor.

Blower Motor

Installation

1. To install, reverse the removal procedure.

    Heating and Defrosting
    The heating and defrosting system has the following features: Controls the temperature and, during A/C operation, reduces the relative humidity of the air inside the vehicle. Delivers heated or ...

    Evaporator Core Housing
    Material Item Specification PAG Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) WSH-M1C231- B MERPOL NA ESE-M99B144- B Removal NOTE: The evapor ...

    Other materials:

    Refueling
    WARNING: Fuel vapor burns violently and a fuel fire can cause severe injuries. To help avoid injuries to you and others: • Read and follow all the instructions on the pump island. • Turn off your engine when you are refueling. • Do not smoke if you are n ...

    Noise, Vibration and Harshness (NVH) (Diagnosis and Testing)
    Special Tool(s) ChassisEAR 107-R2102 or equivalent Electronic Vibration Analyzer 100-F027 (014-00344) or equivalent EngineEAR 107-R2100 or equivalent Ultrasonic Leak Detector 134-R0135 or equivalent T ...

    Key Programming - Erase All Key Codes and Program Two Keys
    Special Tool(s) Worldwide Diagnostic System (WDS) 418-F224, New Generation STAR (NGS) Tester 418-F052 or equivalent diagnostic tool NOTE: This procedure is used when a customer needs keys programmed into the system and does not have ...