Ford Mustang (1999-2004) Service Manual: Blower Motor
Removal
1. Disconnect the jumper wire.

2. Disconnect the main harness.

3. Remove the screws.

4. Separate the cover from the motor.

5. Separate the motor from the housing.

6. Disconnect the jumper from the motor.
- Remove the blower motor.

Installation
1. To install, reverse the removal procedure.
Heating and Defrosting
The heating and defrosting system has the following features:
Controls the temperature and, during A/C operation, reduces the relative
humidity of the air
inside the vehicle.
Delivers heated or ...
Evaporator Core Housing
Material
Item
Specification
PAG Compressor Oil (R-134a
Systems)
F7AZ-19589-DA (Motorcraft
YN-12-C)
WSH-M1C231-
B
MERPOL
NA
ESE-M99B144-
B
Removal
NOTE: The evapor ...
Other materials:
Hill start assist
WARNING: The hill start assist feature does not replace the
parking brake. When you leave the vehicle, always apply the
parking brake and shift the transmission into position P for automatic
transmission or position 1 for manual transmissions.
WARNING: You mus ...
Link - Stabilizer Bar
Removal
CAUTION: Suspension fasteners are critical parts because they affect
performance of vital
components and systems and their failure can result in major service expense. A
new part with
the same part number must be installed if installation becomes nec ...
Exhaust Manifold LH
Removal and Installation
1. Position the steering wheel straight ahead and lock the column.
2. Disconnect the battery ground cable. For additional information, refer to
Section.
3. Raise the vehicle. For additional information, refer to Section.
4. Remove ...