Ford Mustang (1999-2004) Service Manual: Blower Motor

Removal

1. Disconnect the jumper wire.

Blower Motor

2. Disconnect the main harness.

Blower Motor

3. Remove the screws.

Blower Motor

4. Separate the cover from the motor.

Blower Motor

5. Separate the motor from the housing.

Blower Motor

6. Disconnect the jumper from the motor.

  • Remove the blower motor.

Blower Motor

Installation

1. To install, reverse the removal procedure.

    Heating and Defrosting
    The heating and defrosting system has the following features: Controls the temperature and, during A/C operation, reduces the relative humidity of the air inside the vehicle. Delivers heated or ...

    Evaporator Core Housing
    Material Item Specification PAG Compressor Oil (R-134a Systems) F7AZ-19589-DA (Motorcraft YN-12-C) WSH-M1C231- B MERPOL NA ESE-M99B144- B Removal NOTE: The evapor ...

    Other materials:

    Fuse specification chart
    Power Distribution Box WARNING: Always disconnect the battery before servicing high current fuses. WARNING: To reduce risk of electrical shock, always replace the cover to the power distribution box before reconnecting the battery or refilling fluid reservoirs ...

    Actuator Cable - Speed Control
    1. Remove the speed control actuator cable end from the throttle body. 1. Lift the speed control cable from the throttle nailhead. 2. Release the speed control cable from the throttle bracket. 2. Remove the speed control cable from the retaining cli ...

    Accelerator Cable - 4.6L (2V)
    Removal and Installation 1. Push the accelerator cable nylon bushing out of the accelerator pedal and shaft arm. 2. Remove the bolts retaining the accelerator cable to the dash panel. 3. Disconnect the accelerator cable from the throttle body by rotating ...