Ford Mustang (1999-2004) Service Manual: Camshaft Lobe Lift
Special Tool(s)
|
|
Dial Indicator Gauge with Holding Fixture 100-002 (TOOL-4201-C) or equivalent |
1. Use a Dial Indicator Gauge with Holding Fixture to measure camshaft intake/exhaust lobe lift.
- Rotate the camshaft and subtract the lowest indicator reading from the highest indicator reading to figure the camshaft lobe lift.
- Refer to the appropriate section in Group 303 for the procedure.

Camshaft End Play - OHC Engines
Special Tool(s)
Dial Indicator Gauge with
Holding Fixture
100-002 (TOOL-4201-C) or
equivalent
1. Remove the roller followers. Refer to the appropriate section in Group 303
for the ...
Camshaft Runout
Special Tool(s)
Dial Indicator Gauge with
Holding Fixture
100-002 (TOOL-4201-C) or
equivalent
1. NOTE: Camshaft journals must be within specifications before
checking runout.
Use ...
Other materials:
Deactivation Procedure
WARNING: If the supplemental restraint system (SRS) is being serviced,
the system must
be deactivated and restraint system diagnostic tools must be installed. Refer to
Air Bag
Supplemental Restraint System (SRS) in this section.
The air bag restraint system ...
Reversing Lamps
Refer to Wiring Diagrams Cell 93 , Backup Lamps for schematic and
connector information.
Special Tool(s)
73III Automotive Meter or
equivalent
105-R0057
Inspection and Verification
1. Verify the customer concern by operating the reversing l ...
Air Cleaner Outlet Pipe - 3.8L
Removal and Installation
1. Remove the air cleaner outlet tube.
1. Loosen the clamps.
2. Disconnect the hose.
3. Remove the tube.
2. To install, reverse the removal procedure.
Air Cleaner Outlet Pipe -4.6L (2V)
Removal and Installation
1. Dis ...