Ford Mustang (1999-2004) Service Manual: Camshaft Lobe Lift

Special Tool(s)

Dial Indicator Gauge with Holding Fixture 100-002 (TOOL-4201-C) or equivalent

1. Use a Dial Indicator Gauge with Holding Fixture to measure camshaft intake/exhaust lobe lift.

  • Rotate the camshaft and subtract the lowest indicator reading from the highest indicator reading to figure the camshaft lobe lift.
  • Refer to the appropriate section in Group 303 for the procedure.

Camshaft Lobe Lift

    Camshaft End Play - OHC Engines
    Special Tool(s) Dial Indicator Gauge with Holding Fixture 100-002 (TOOL-4201-C) or equivalent 1. Remove the roller followers. Refer to the appropriate section in Group 303 for the ...

    Camshaft Runout
    Special Tool(s) Dial Indicator Gauge with Holding Fixture 100-002 (TOOL-4201-C) or equivalent 1. NOTE: Camshaft journals must be within specifications before checking runout. Use ...

    Other materials:

    Inspection and Verification
    WARNING: Batteries contain sulfuric acid. Avoid contact with skin, eyes, or clothing. Also, shield your eyes when working near batteries to protect against possible splashing of the acid solution. In case of acid contact with skin or eyes, flush ...

    Suction Accumulator
      NOTE: Installation of a new suction accumulator is not required when repairing the air conditioning system except when there is physical evidence of contamination from a failed A/C compressor or damage to the suction accumulator. In addition to th ...

    Changing a bulb
    Lamp Assembly Condensation Exterior lamps are vented to accommodate normal changes in pressure. Condensation can be a natural by-product of this design. When moist air enters the lamp assembly through the vents, there is a possibility that condensation can oc ...